Tim Kelley on tue 22 jul 08
=20
=20
I noticed while firing a load of bisque that the top two elements were
not working. The kiln is a Paragon A82b,Would any one know what the
proper sequence is to trouble shoot this Problem.
=20
Tim Kelley
Castroville Texas
Clay@buysunrise.com
L TURNER on wed 23 jul 08
Tim Kelley wrote:
>
> I noticed while firing a load of bisque that the top two elements were
> not working. The kiln is a Paragon A82b,Would any one know what the
> proper sequence is to trouble shoot this Problem.
>
Tim,
Step 1 is to call Arnold Howard at Paragon.
here is his contact information.
Arnold Howard
Paragon Industries, L.P.
2011 South Town East Blvd., Mesquite, TX 75149-1122
Voice: 972-288-7557 & 800-876-4328 / Fax: 972-222-0646
www.paragonweb.com
L. Turner
Arnold Howard on wed 23 jul 08
From: "Tim Kelley"
I noticed while firing a load of bisque that the top two
elements were
not working. The kiln is a Paragon A82b
---------------
The top two elements are controlled by the top switch. You
can find the wiring diagram here:
http://www.paragonweb.com/files/wiringdiagrams
Click on this link:
http://www.paragonweb.com/Instruction_Manuals.cfm
Then scroll down to "Ohmmeter Instructions for Testing
A-Series Kilns." The ohmmeter can test the entire electrical
system from the plug.
Sincerely,
Arnold Howard
Paragon Industries, L.P., Mesquite, Texas USA
ahoward@paragonweb.com / www.paragonweb.com
| |
|