David Woodin on thu 1 jun 00


The surging of the Brent wheels is caused by the voltage dropping everytime
the controller calls for heat. Louis Katz is right and a larger supply
wiring to the kiln will probably cure it. Otherwise a constant voltage
transformer for the wheels would be needed.
David

Craig Martell on thu 1 jun 00


David sez:
>The surging of the Brent wheels is caused by the voltage dropping everytime
>the controller calls for heat. Louis Katz is right and a larger supply
>wiring to the kiln will probably cure it. Otherwise a constant voltage
>transformer for the wheels would be needed.

Thanks David! The wiring for the kiln is more than adequate. It draws 42
ams and that circuit was originally set for a 100 amp kiln. I just put in
a smaller breaker for the reduced amp draw. I'm having the power company
check the transformer at the pole. That may be the problem. If it isn't,
I'll proceed from there.