natural gas needs for raku

updated thu 24 oct 02

 

Bob Pulley on tue 22 oct 02


I am trying to set up a raku station for a high school situation.
The Fire Marshall says no propane in the courtyard behind my room. I
have only rakued with propane. It might be possible to run natural gas
to the site. Does anyone know how large a line or how much preasure is
required to fire raku? Also, will my venturi burners work with drilled
out orfices or will I need a blower?

Bob Pulley

Corinne en Ben on wed 23 oct 02


I have a gas kiln built from fiber board running on natural
gas, and I easily can reach a stoneware temperature.
So you definetely can run a raku kiln on natural gas!
The pressure is not much I'm having. I just have one very big
ventury burner. The pressure is that low that I cannot even
regulate it with a needle valve, I just use a normal tap. It
works.
If you want more details about the burner I'll will look it
up for you.




> I am trying to set up a raku station for a high school
situation.
> The Fire Marshall says no propane in the courtyard behind
my room. I
> have only rakued with propane. It might be possible to run
natural gas
> to the site. Does anyone know how large a line or how much
preasure is
> required to fire raku? Also, will my venturi burners work
with drilled
> out orfices or will I need a blower?
>
> Bob Pulley

Dannon Rhudy on wed 23 oct 02


Bob said:

> I am trying to set up a raku station for a high school ...
might be possible to run natural gas
> to the site.....will my venturi burners work with drilled
> out orfices or will I need a blower?......

You can fire raku on ordinary household pressure with
natural gas. I've done that for a long time. You will need
to change the orifices in your burners, but that's easily done.
You can use a blower to fire more quickly, but one is not
necessary, in my experience.

regards

Dannon Rhudy

Bob Pulley on wed 23 oct 02


Thanks for the tip. I'll just have them run a line out and we'll make
the best of it.
Bob

>>> drhudy@EV1.NET 10/23/02 08:28AM >>>
Bob said:

> I am trying to set up a raku station for a high school ...
might be possible to run natural gas
> to the site.....will my venturi burners work with drilled
> out orfices or will I need a blower?......

You can fire raku on ordinary household pressure with
natural gas. I've done that for a long time. You will need
to change the orifices in your burners, but that's easily done.
You can use a blower to fire more quickly, but one is not
necessary, in my experience.

regards

Dannon Rhudy

______________________________________________________________________________
Send postings to clayart@lsv.ceramics.org

You may look at the archives for the list or change your subscription
settings from http://www.ceramics.org/clayart/

Moderator of the list is Mel Jacobson who may be reached at
melpots@pclink.com.

Snail Scott on wed 23 oct 02


At 04:40 PM 10/22/02 -0500, you wrote:
>...Also, will my venturi burners work with drilled
>out orfices or will I need a blower?


You should be able to replace just the orifices
with the natural-gas-sized type.

-Snail